Icon Créer jeu Créer jeu
Obtenir Plan Académique
Obtenir Plan Académique
Obtenir Plan Académique

Fire and Life Safety Building Services Game (24)

Oui ou Non

(6)
Test your knowledge on the fire and life safety aspects of building services with this interactive game!

Téléchargez la version pour jouer sur papier

131 fois fait

Créé par

United States
Ce jeu est une version de

Top 10 résultats

  1. 1
    01:03
    temps
    95
    but
  2. 2
    Vincent Lovato
    Vincent Lovato
    02:25
    temps
    90
    but
  3. 3
    01:59
    temps
    80
    but
  4. 4
    Guillermo
    Guillermo
    02:00
    temps
    60
    but
Voulez-vous apparaître dans le Top 10 de ce jeu? pour vous identifier.
Créez votre propre jeu gratuite à partir de notre créateur de jeu
Affrontez vos amis pour voir qui obtient le meilleur score dans ce jeu

Top Jeux

  1. temps
    but
  1. temps
    but
temps
but
temps
but
 
game-icon

Fire and Life Safety Building Services Game (24)Version en ligne

Test your knowledge on the fire and life safety aspects of building services with this interactive game!

par Suzanne Freeman
1

Grease ducts are made of combustible materials.

2

Kitchen grease exhaust ducts do not require any fire-resistive separation.

3

Utility chases can be used for plumbing, electrical raceways, telecommunications, data cables, and HVAC ductwork.

4

Subsystems must be appropriately installed, inspected, tested, and maintained to ensure building system safety.

5

Hoistways are constructed of combustible materials and do not have fire-rated door assemblies.

6

Grease ducts are typically installed over cooking appliances and carry grease vapors to the outside of a building.

7

Wiring, ductwork, and piping should be run within the elevator hoistway.

8

Refuse and linen chutes are not required to be constructed of fire-resistive construction.

9

Proper installation of grease ducts ensures that grease does not become trapped and cause a fire.

10

Kitchen grease exhaust ducts always require 1-hour fire-resistive separation.

11

Building services are designed to create fire hazards within a building.

12

Vertical shafts are primarily used for storage of flammable materials.

13

Refuse and linen chutes are required to be constructed of fire-resistive construction and may require sprinkler protection.

14

Building services are designed to provide safety, comfort, and convenience for occupants.

15

The use of a fire-resistive-rated duct wrap system can accomplish the 1-hour fire-resistive separation requirement.

16

Elevator hoistways are equipped with fire-rated door assemblies.

17

Defective subsystems have no effect on the overall building system.

18

Grease ducts are not necessary for all cooking appliances.

19

Commercial cooking venting systems may require automatic fire suppression equipment.

20

Utility chases are occupied spaces within a building.